Quality verification for water repellent treatments — objectively measured.

Using the electrolyte measurement method, we test the quality of water repellent treatments (surface protection system OS-A) directly on the structure — according to ZTV-ING specifications and using our own measuring device.

Concrete wall on a road construction project for hydrophobic treatment against penetrating moisture

What It’s About

Checking if the water repellent treatment performs as intended.

Whether a water repellent treatment has been applied professionally cannot be judged with the naked eye. As an expert service, we offer metrological quality testing — non-destructive, directly on the concrete surface.

The basis is the test procedure for the “determination of the quality of water repellent treatments” regulated in ZTV-ING Part 3, Section 4, Appendix B. It is based on current transport in electrolytic solutions: special sensors release an electrolyte liquid (limewater) onto the surface under defined conditions and record its resistance.

We use the same process to determine the appropriate consumption rate of a deep-penetrating water repellent — such as our Protector OCI — before execution and to verify professional application after execution.

|

with our own measuring device

Why the inspection

Certainty for clients, planners, and contractors.

Determine consumption

Using sample areas, we determine the correct object-specific application rate per square meter — the basis for tendering and calculation.

Verify execution

After application, the measurement proves that the water repellent treatment achieves the required quality — reliable proof for final acceptance.

Standard-compliant documentation

Measurement and evaluation are carried out according to ZTV-ING — transparently documented for procurement, warranty, and operation.

Three steps on the structure

How the inspection works.

From preparation to the evaluated measurement — every step documented.

Non-destructive measurement of concrete residual moisture before water repellent treatment

Determine residual moisture

The measurement results depend heavily on concrete moisture and object temperature. Therefore, the residual moisture is measured non-destructively in advance to a depth of around 40 mm.

Create sample areas

To determine the correct consumption rate, we create sample areas with different application rates — typically 400, 500, and 600 g per square meter.

This allows for an object-specific determination of which quantity achieves the required protective effect — the binding basis for execution.

Sample areas with 400, 500, and 600 g/m² to determine the consumption rate of a deep-penetrating water repellent
Water repellent measuring device HDBMG-02 for quality inspection of water repellent treatments according to ZTV-ING

Perform electrolyte measurement

The sensors are placed on the concrete surface and release limewater under defined conditions. The resistance of the surface is recorded via the current transport in this solution — on the treated surface and in comparison with a reference surface.

Evaluation

15 minutes — and 60 if necessary.

The assessment follows the testing times specified in the ZTV-ING.

15 min.

Initial evaluation

After a measurement duration of 15 minutes, the average value is evaluated. If it is below the required limit, the sufficient quality of the water repellent treatment is proven.

60 min.

Extended evaluation

If the limit is exceeded after 15 minutes, the measurement is continued and re-evaluated after 60 minutes.

Protective effect in practice

Protection starts before cleaning is needed.

Anti-graffiti protection does not only show its effect during later cleaning. In this practical test, you can already see while spraying on how paint behaves differently on a vertical surface protected with AGS Protector Perma Color and AGS Protector P Innovation.

With many of the paints tested, no uniform graffiti image can form even while spraying on.

View further case studies on surfaces already treated:

Frequently asked questions and answers about the electrolyte measurement method

Does the process also record the penetration depth?

No. The procedure according to ZTV-ING Appendix B is a pure surface testing method. It evaluates tightness and resistance directly at the concrete surface, but provides no information about depth-dependent effectiveness or the actual penetration depth in the concrete structure.

For exact proof of effectiveness at depth or a minimum penetration depth (≥ 6 mm), additional laboratory tests are required — such as core sampling followed by optical or chemical analysis according to TR Instandhaltung. We offer both as a coordinated package.

Yes. The electrolyte measurement takes place directly on the component without damaging it. Only an additional depth verification via drill core requires material removal.

After a measurement duration of 15 minutes, the average value is evaluated. If it is below the required limit, sufficient quality is proven. If the limit is exceeded, the measurement is continued and re-evaluated after 60 minutes.

Need to test or verify a water repellent treatment?

Describe your object and requirements to us — we will coordinate the testing concept according to ZTV-ING and get back to you within 24–48 hours.